  Abstract 


Objective: We had evaluated our experience in the treatment of Morrey Modified Masons type III and IV radial head fractures with radial head prosthesis. Materials and Methods: From April 2011 to September 2014, modular radial head prostheses were performed in thirty patients. There were twenty female and ten male with mean age of forty years. The follow-up was a mean of 25 months. Fractures of the radial head have been classified by Morrey Modified Masons classification. The indications for a radial head replacement were type III fractures in 24 cases, type IV fractures in 6 cases, and comminuted radial fracture associated with disruption of the medial collateral ligament in 3 cases. Patients were assessed postoperatively and on follow-up based on Mayo Elbow Performance Index (MEPI) Score. Results: By using the MEPI, out of thirty cases, twenty cases had excellent results, seven cases had good results, two cases had fair results, and one case had poor result. Twenty-eight cases had no complications, one case had infection, and one case had implant failure. Conclusion: Modular radial head prosthesis can be used successfully for treatment of the Morrey Modified Masons type III and IV radial head fractures.

Keywords: Comminuted radial head fractures, radial head arthroplasty, radial head prosthesis


How to cite this article:
Bagul RR, Deo S, Salgia A, Sooknandan M, Patole V. Study of role of prosthetic replacement for comminuted fracture of head of radius. Med J DY Patil Univ 2016;9:474-8

How to cite this URL:
Bagul RR, Deo S, Salgia A, Sooknandan M, Patole V. Study of role of prosthetic replacement for comminuted fracture of head of radius. Med J DY Patil Univ [serial online] 2016 [cited 2024 Mar 28];9:474-8. Available from: https://journals.lww.com/mjdy/pages/default.aspx/text.asp?2016/9/4/474/186071




  Introduction Top


The incidence of radial head fractures has been reported to be between 1.7% and 5.4% of all fractures and represents 33% of all elbow fractures.[1],[2],[3] The most common injury mechanism is due to an axial load onto the pronated and extended forearm. The radial head provides stability about the elbow and forearm by acting as a secondary stabilizer to valgus instability of the elbow, with the primary stabilizer being the medial collateral ligament (MCL) and by providing stability to the distal radial ulnar joint to assist the forearm in resisting axial forces and enhancing grip strength.[4],[5] There are several patterns of complex injury that include a fracture of the radial head. Identification of these injury patterns can help guide treatment. These patterns include (i) fracture of radial head associated with rupture of MCL (ii) concomitant fractures of the radial head and capitellum (iii) posterior dislocation of the elbow with fracture of the radial head (iv) posterior dislocation of the elbow with fracture of the radial head and coronoid process (the so-called terrible triad of the elbow) (v) posterior Monteggia fractures including posterior olecranon fracture-dislocations and (vi) Essex–Lopresti lesions and variants.[6] Radial head arthroplasty is indicated in unreconstructable head fractures and in cases of associated elbow instability for which excision of the radial head will likely produce late complications. Speed in 1941 first proposed prosthetic replacement of the radial head using a ferrule cup over the neck of radius.[7] Since then, the use of acrylic, silicone, vitallium, and other metallic radial head prostheses has been reported each with varying results. The purpose of this study was to evaluate our experience in the treatment of Morrey Modified Masons type III and IV radial head fractures with modular radial head prosthesis.


  Materials and Methods Top


The present study consists of 30 patients of Morrey Modified Masons type III and IV radial head fractures treated by modular radial head prosthesis from April 2011 to September 2014.

Inclusion criteria

  1. Morrey Modified Masons type III and IV fractures.
  2. Closed fractures.
  3. Age of patient 20 years and more.
  4. Delay at presentation of not more than 2 weeks.


Exclusion criteria

  1. Morrey Modified Masons type I and type II fracture.
  2. Open fractures.
  3. Presence of any infection.
  4. Patients with age <20 years.


Ethical

Ethics Committee approval was obtained before start of the study. An informed and written consent was taken from patients and relatives in their local language.

Preoperative

On admission, a detailed history including the mechanism of injury and the complaints of the patients were noted, along with a thorough clinical examination. Radiographs of affected limb elbow anteroposterior and lateral views were taken [Figure 1] and [Figure 2]. For primary treatment, immobilization was given in the form of a slab. All routine investigations were done prior to anesthesia fitness.
Figure 1: Patient 1-Preoperative X-ray elbow anteroposterior and lateral views

Click here to view
Figure 2: Patient 2-Preoperative X-ray elbow anteroposterior and lateral views

Click here to view


Operative

Under general or regional anesthesia, the patient was positioned in the supine position. After routine preparation and draping, Kocher approach was made to expose the radial head. The fractured radial head was excised with great care taken not to leave any fragment in the elbow joint. Copious joint irrigation was performed to remove all loose intraarticular debris. Valgus and axial stress tests were performed using an image intensifier to evaluate the competency of the MCL and interosseous ligament. A modular radial head implant system was used. This device has multiple head diameters and heights and different stem sizes, which allows for a close approximation to normal anatomy. Each head could be mated to any of the stems using a Morse taper resulting in multiple potential combinations of sizes. The different head heights accommodated for the extension of fractures into the proximal neck and also accounted for observed variability in head height. The parts of the broken head were reassembled on the table to ensure that the whole head had been resected to choose the size of the prosthetic head. A minimal amount of radial neck was resected at a right angle to the medullary canal of the radial neck to ensure a smooth surface for load transfer to the implant. The appropriate diameter and height of radial head implant were selected for trial implantation. The medullary canal of the radial neck was gently rasped using the hand reamers. Rasp was used to smooth the neck cut, ensuring that it was at 90° to the neck and the trial head was inserted onto the trial stem. The diameter, height, and congruency of the prosthesis were assessed visually with the aid of an image intensifier. The head had to reach the limit between the trochlear notch and the radial notch of the ulna. The trial components were removed and the definitive implants were inserted with cementing. After radial head replacement, the annular ligament was repaired. The fascial interval between the anconeus and extensor carpi ulnaris was closed. Wound was closed and tourniquet deflated. Associated procedures include MCL repair in three cases. Postoperative X-ray was taken [Figure 3] and [Figure 4].
Figure 3: Patient 1-Post-operative X-ray elbow anteroposterior and lateral views

Click here to view
Figure 4: Patient 2- Post-operative X-ray elbow anteroposterior and lateral views

Click here to view


Physiotherapy

Patients with a stable elbow started with active flexion and extension exercises throughout a full arc of motion, 3 days after surgery. A collar and cuff was worn during the day between exercises. In patients with associated ligamentous injuries, a resting splint with the elbow maintained at 90° was used for 4 weeks. Active flexion and extension exercises throughout a full arc of motion were started after 4 weeks.

Follow-up

The patients were followed up in outpatient department fortnightly for a period of 1 month postoperatively. Physiotherapy was continued. At follow-up, patients were examined clinically for a range of movements and then radiologically at the end of 6 weeks, 12 weeks, 6 months, and 1 year. The patients were assessed postoperatively and on follow-up based on Mayo Elbow Performance Index (MEPI) Score.[8]

Greater than 90 points = excellent, 75-89 points = good, 60-74 points = fair, and <60 points = poor.


  Observation and Results Top


In our case study of 30 cases, 16 cases were <40 years (53.33%) and 14 cases were more than 40 years, (46.67%) the mean age was 39.8 years, maximum age was 56 years, and minimum age was 30 years [Table 1].
Table 1: Age distribution

Click here to view


Twenty cases (66.67%) were female and 10 cases (33.33%) were male. The mode of injury in 20 cases (66.67%) was due to fall and in 10 cases (33.33%) was due to road traffic accident. Twenty cases (66.67%) involved the right elbow and 10 cases (33.33%) involved the left elbow. Twenty-three cases (76.67%) were right side dominant and 7 cases (23.33%) were left side dominant.

Twenty-four cases (80%) were under Morrey Modified Mason's classification type III and 6 cases (20%) were under Morrey Modified Mason's classification type IV [Table 2].
Table 2: Morrey modified Mason's classification

Click here to view


Twenty-seven cases (90%) were not associated with any ligamentous injury and 3 cases (10%) were associated with MCL injury. Average follow-up was for 25 months. Range of movement in average flexion was 140 degrees, average extension deficit was 10°, average pronation was 75°, and average supination was 68°.

By using the Mayo Elbow Performance Index, 20 cases (66.67%) had excellent results, 7 cases (23.33%) had good results, 2 cases (6.67%) had fair results, and 1 case (3.33%) had poor result [Table 3].
Table 3: Mayo Elbow Performance Index

Click here to view


In 15 cases (50%), 20 mm implant size was used, in 10 cases (33.33%), 18 mm implant size was used, and in 5 cases (16.67%), 22 mm implant size was used.

Postoperatively, 28 cases (93.33%) had no complications, 1 case had infection (3.33%), and one case had implant failure (3.33%) [Table 4].
Table 4: Postoperative complication

Click here to view



  Discussion Top


In 1954, Mason classified radial head fractures into three types. Type 1 - undisplaced segmental or marginal fractures, Type 2 - displaced fractures involving part of the head, and Type 3 - comminuted fractures of the entire head.[9] In 1985, Morrey Modified Mason's classification to include radial head fractures associated with posterior dislocation of the elbow as suggested by Johnston as a Mason Type 4 fracture.[10] In discussing the treatment of severely comminuted radial head fractures, most authors until the 1950s considered excision as the only modality of treatment. But after radial head excision, local formation of new bone and proximal displacement of the radial shaft were the two factors, which would impair the function of the elbow and also cause persistent pain of elbow and wrist.[9],[10],[11] Speed in 1941 first proposed prosthetic replacement of the radial head.[7] Acrylic radial head prostheses were introduced but were discarded due to fractures of the prosthesis itself. Silastic prosthesis was introduced in the 1970s. It acted as a spacer only without giving any biomechanical advantage in weight transmission and also caused synovitis.[12],[13],[14],[15],[16] The search for a stiffer material for prosthesis manufacture resulted in the use of various metals such as vitallium, stainless steel, and most recently titanium. Literature supports metallic radial head replacement as it restores the axial stiffness of the forearm to normal whereas excision allows abnormal proximal migration, especially under load.[17],[18] The complications with arthroplasty are subluxation or dislocation, painful loosening, implant impingement, and fracture of the prosthesis.[19],[20] Van Riet et al.[21] have showed capitellar erosion caused by metal radial head prosthesis. Van Glabbeek et al.[22] suggests that accurate restoration of radial length is important and that axial understuffing or overstuffing of the radiohumeral joint by more than 2.5 mm alters both elbow kinematics and radiocapitellar pressure.

The incidence of capitellar chondral injury is 20% in Mason types II and III according to one study.[23] There are few articles with long-term outcomes following capitellar cartilage injury. In our study, we did not have any case with capitellar chondral injury. The Essex–Lopresti lesion is an axial instability of the forearm due to the distal radioulnar joint dislocation with rupture of the interosseous ligament in association with a radial head fracture.[24] In our study, we did not have any case with Essex–Lopresti lesion.

Chen et al.[25] conducted a prospective randomized trial on radial head prosthesis versus open reduction and internal fixation in 45 patients with Mason type III radial head fractures between January 2004 and June 2007. The satisfaction levels according to the Broberg and Morrey Rating Index were higher in the replacement group. The postoperative complication rate was lower in the replacement group (P< 0.01).

Smets et al.[26] reported results from their multicenter trial using a bipolar prosthesis (Tornier Inc., Montbonnot-Saint-Martin, France) after 25.2 months of average follow-up. In this study, 13 Mason type III fractures were managed by radial head replacements. The average age was 46 years. Moro et al.[27] completed a retrospective study of 10 patients with Mason type III fractures treated with radial head replacements (Smith and Nephew Richards, Memphis, TN, USA) over an average of 2 years. The average age was 47 years. In our case study of 30 patients using bipolar radial head prosthesis, 24 cases were type III and 6 cases were type IV. There were 20 female and 10 male with mean age of 40 years. The follow-up was a mean age of 25 months.

Smets et al.[26] reported active flexion averaged 135.5°, extension deficit averaged 16.3°, active pronation averaged 79.3°, and active supination averaged 83°. Moro et al.[27] reported both assessments comparing the function of the injured arm with the contralateral arm. Average pronation was 78° compared to 79°, supination 69° compared to 77°, elbow flexion 140° compared to 143°, and elbow extension deficit was 8° compared to full extension on the uninjured side (P< 0.05). In our study, average flexion was 140°, average extension deficit was 10°, average pronation was 75°, and average supination was 68°.

In Smets et al.[26] study according to MEPI Score seven had excellent, three had good, one had fair and two had poor outcomes. One patient with a poor outcome required removal of prosthesis. According Moro et al.[27] study six patients suffered complications, including elbow stiffness, ulnar nerve dysesthesia, varying levels of heterotopic ossification, one superficial infection and one patient developed a regional sympathetic -mediated pain syndrome. Accordingly the MEPI three patients had poor outcomes. In our study, according to MEPI score, 20 cases had excellent results, 7 cases good results, 2 cases fair results and 1 case had poor result. 28 cases had no complications, 1 case had infection and 1 case had implant failure.

Our short term results mean follow-up of 25 months looks good, but we will continue our follow-up to look for long-term results.


  Conclusion Top


Modular radial head prosthesis can be used successfully for treatment of the Morrey Modified Masons type III and IV radial head fractures.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

 
  References Top

1.
Calfee R, Nadom I, Weiss AP. Radial head arthroplasty. J Hand Surg 2006;31A:314-21.  Back to cited text no. 1
    
2.
Frank SG, Grewal R, Johnson J, Faber KJ, King GJ, Athwal GS. Determination of correct implant size in radial head arthroplasty to avoid overlengthening. J Bone Joint Surg Am 2009;91: 1738-46.  Back to cited text no. 2
    
3.
Morgan WJ. Fractures of the radial head. Am Acad Soc Surg Hand 2001;1:225-35.  Back to cited text no. 3
    
4.
Hotchkiss RN. Displaced fractures of the radial head: Internal fixation or excision? J Am Acad Orthop Surg 1997;5:1-10.  Back to cited text no. 4
    
5.
Morrey BF, Chao EY, Hui FC. Biomechanical study of the elbow following excision of the radial head. J Bone Joint Surg Am 1979;61:63-8.  Back to cited text no. 5
[PUBMED]    
6.
Bucholz RW, Court-Brown CM, Heckman JD, Tornette P. Rockwood and Green's Fractures in Adults. 7th ed. Philadelphia: Lippincott Williams and Wilkins; 2010. p. 911-8.  Back to cited text no. 6
    
7.
Speed K. Ferrule caps for the head of the radius. Surg Gynecol Obstet 1941;73:845-50.  Back to cited text no. 7
    
8.
Morrey BF. Prosthetic radial head replacement. In: Morrey BF, Sanchez-Sotelo J, editors. The Elbow and Its Disorders. Philadelphia: WB Saunders Elsevier; 2009. p. 381-8.  Back to cited text no. 8
    
9.
Mason ML. Some observations on fractures of the head of the radius with a review of one hundred cases. Br J Surg 1954;42:123-32.  Back to cited text no. 9
[PUBMED]    
10.
Morrey BF, editor. Radial head fractures. In: The Elbow and Its Disorders. Philadelphia: WB Saunders; 1985. p. 355.  Back to cited text no. 10
    
11.
Johnston GW. A follow-up of one hundred cases of fracture of the head of the radius with a review of the literature. Ulster Med J 1962;31:51-6.  Back to cited text no. 11
[PUBMED]    
12.
Hotchkiss RN, Weiland AJ. Valgus stability of the elbow. J Orthop Res 1987;5:372-7.  Back to cited text no. 12
[PUBMED]    
13.
Carn RM, Medige J, Curtain D, Koenig A. Silicone rubber replacement of the severely fractured radial head. Clin Orthop Relat Res 1986;(209):259-69.  Back to cited text no. 13
[PUBMED]    
14.
Stoffelen DV, Holdsworth BJ. Excision or Silastic replacement for comminuted radial head fractures. A long-term follow-up. Acta Orthop Belg 1994;60:402-7.  Back to cited text no. 14
    
15.
Vanderwilde RS, Morrey BF, Melberg MW, Vinh TN. Inflammatory arthritis after failure of silicone rubber replacement of the radial head. J Bone Joint Surg Br 1994;76:78-81.  Back to cited text no. 15
    
16.
Pribyl CR, Kester MA, Cook SD, Edmunds JO, Brunet ME. The effect of the radial head and prosthetic radial head replacement on resisting valgus stress at the elbow. Orthopedics 1986;9:723-6.  Back to cited text no. 16
[PUBMED]    
17.
Ashwood N, Bain GI, Unni R. Management of Mason type-III radial head fractures with a titanium prosthesis, ligament repair, and early mobilization. J Bone Joint Surg Am 2004;86-A:274-80.  Back to cited text no. 17
    
18.
Bain GI, Ashwood N, Baird R, Unni R. Management of Mason type-III radial head fractures with a titanium prosthesis, ligament repair, and early mobilization. Surgical technique. J Bone Joint Surg Am 2005;87 Suppl 1(Pt 1):136-47.  Back to cited text no. 18
    
19.
King GJ. Management of comminuted radial head fractures with replacement arthroplasty. Hand Clin 2004;20:429-41, vi.  Back to cited text no. 19
    
20.
Wretenberg P, Ericson A, Stark A. Radial head prosthesis after fracture of radial head with associated elbow instability. Arch Orthop Trauma Surg 2006;126:145-9.  Back to cited text no. 20
    
21.
Van Riet RP, Van Glabbeek F, Verborgt O, Gielen J. Capitellar erosion caused by a metal radial head prosthesis. A case report. J Bone Joint Surg Am 2004;86-A:1061-4.  Back to cited text no. 21
    
22.
Van Glabbeek F, Van Riet RP, Baumfeld JA, Neale PG, O'Driscoll SW, Morrey BF, et al. Detrimental effects of overstuffing or understuffing with a radial head replacement in the medial collateral-ligament deficient elbow. J Bone Joint Surg Am 2004;86-A:2629-35.  Back to cited text no. 22
    
23.
Nalbantoglu U, Gereli A, Kocaoglu B, Aktas S, Turkmen M. Capitellar cartilage injuries concomitant with radial head fractures. J Hand Surg Am 2008;33:1602-7.  Back to cited text no. 23
    
24.
Duckworth AD, Clement ND, Aitken SA, Ring D, McQueen MM. Essex-Lopresti lesion associated with an impacted radial neck fracture: Interest of ulnar shortening in the secondary management of sequelae. J Shoulder Elbow Surg 2011;20:e19-24.  Back to cited text no. 24
    
25.
Chen X, Wang SC, Cao LH, Yang GQ, Li M, Su JC. Comparison between radial head replacement and open reduction and internal fixation in clinical treatment of unstable, multi-fragmented radial head fractures. Int Orthop 2011;35:1071-6.  Back to cited text no. 25
    
26.
Smets S, Govaers K, Jansen N, Van Riet R, Schaap M, Van Glabbeek F. The floating radial head prosthesis for comminuted radial head fractures: A multicentric study. Acta Orthop Belg 2000;66:353-8.  Back to cited text no. 26
    
27.
Moro JK, Werier J, MacDermid JC, Patterson SD, King GJ. Arthroplasty with a metal radial head for unreconstructible fractures of the radial head. J Bone Joint Surg Am 2001;83-A:1201-11.  Back to cited text no. 27
    


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4]
 
 
    Tables

  [Table 1], [Table 2], [Table 3], [Table 4]



 

Top
   
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
Abstract
Introduction
Materials and Me...
Observation and ...
Discussion
Conclusion
References
Article Figures
Article Tables

 Article Access Statistics
    Viewed2926    
    Printed94    
    Emailed0    
    PDF Downloaded188    
    Comments [Add]    

Recommend this journal